News · CISA ICS Advisories
-
CISA ICS Advisories
EPICS Base
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition, corrupt memory, disclose sensitive information, or potentially execute arbitrary code. The following versions of EPICS Base are affected: EPICS Base release <=7.0.10 (CVE-2026-114595, CVE-2026-114596, CVE-2026-114597, CVE-2026-114598) CVSS Vendor Equipment v3 9.8 The EPICS Community EPICS Base release 3 Vulnerabilities Integer Overflow or Wraparound, Improper Handling of Length Parameter Inconsistency, Access of Resource Using Incompatible Type ('Type Confusion')…
CVE-2026-114595, CVE-2026-114596, CVE-2026-114597 +1 -
CISA ICS Advisories
Mitsubishi Electric GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32 and BizViz
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code (CVE-2023-4863), bypass authentication (CVE-2026-16436 and CVE-2026-16437), or perform arbitrary operations (CVE-2026-16438), resulting in information disclosure, tampering with, destruction, or deletion of information, and a denial-of-service (DoS) condition of the system. The following versions of Mitsubishi Electric GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32 and BizViz are affected: Mitsubishi Electric GENESIS64 >=…
CVE-2023-4863, CVE-2026-16436, CVE-2026-16437 +1 -
CISA ICS Advisories
Siemens SIMATIC S7 Webserver API
View CSAF Summary .NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory. Siemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version. The following versions of Siemens SIMATIC S7 Webserver API are affected: .NET Client Library for SIMATIC S7 Webserver API vers:intdot/<3.3.61, vers:intdot/<3.3.62 (CVE-2026-85114, CVE-2026-85115) CVSS Vendor Equipment v3 7.5 Siemens .N…
CVE-2026-85114, CVE-2026-85115 -
CISA ICS Advisories
Siemens SIMATIC S7-1500 TM MFP
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1.1. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 TM MFP are affected: SIMATIC S7-1500 TM MFP - GNU/Linux subsystem vers:all/* CVSS Vendor Equipment v3 10 Siemens SIMATIC S7-1500 TM MFP - GNU/Linux subsystem 377 Vulnerabilities Access of Uninitialized Pointer, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Deadlock…
-
CISA ICS Advisories
Siemens RUGGEDCOM APE1808 Devices
View CSAF Summary Nozomi Networks has published information on vulnerabilities in Nozomi Guardian/CMC. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens recommends to contact customer support to receive patch and update information. The following versions of Siemens RUGGEDCOM APE1808 Devices are affected: RUGGEDCOM APE1808 vers:all/* (CVE-2026-33387, CVE-2026-33388, CVE-2026-33389, CVE-2026-33391, CVE-2026-33920) CVSS Vendor Equipment v3 7.5 Siemens RUGGEDCOM APE1808 4 Vulnerabilities Improper Neutralization of Special Elements Used in a Te…
CVE-2026-33387, CVE-2026-33388, CVE-2026-33389 +2 -
CISA ICS Advisories
Siemens Industrial Edge Devices
View CSAF Summary Siemens Industrial Edge Devices contain multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Devices are affected: Industrial Edge Cloud Device (IECD) vers:intdot/<1.28.1 (CVE-2026-44414) Industrial Edge Own…
CVE-2026-44414 -
CISA ICS Advisories
Siemens RUGGEDCOM CROSSBOW Station Access Controller
View CSAF Summary RUGGEDCOM CROSSBOW Station Access Controller (SAC) contains multiple vulnerabilities in the integrated SQLite component that could allow an attacker to execute arbitrary code, cause a denial of service, or obtain sensitive information. Siemens has released a new version for RUGGEDCOM CROSSBOW Station Access Controller (SAC) and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW Station Access Controller are affected: RUGGEDCOM CROSSBOW Station Access Controller (SAC) vers:intdot/<6.0 (CVE-2025-6965, CVE-2025-70873, CVE-2025-71316…
CVE-2025-6965, CVE-2025-70873, CVE-2025-71316 -
CISA ICS Advisories
Siemens SIMATIC S7 PLCs Web Server
View CSAF Summary SIMATIC S7-1500 devices contain multiple vulnerabilities in the web server that could allow an attacker to execute malicious code in an authorized user’s browser session and perform PLC operations within the scope of that user’s authorization. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7 PLCs Web Server are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0) vers:all/* (CVE-2026-63350, CVE-2026-63351, CVE-2026-63352, CVE-2026-63353, CVE-2026-…
CVE-2026-63350, CVE-2026-63351, CVE-2026-63352 +1 -
CISA ICS Advisories
Siemens WinCC
View CSAF Summary Multiple SIMATIC WinCC versions are affected by a database privilege escalation vulnerability that could allow an authenticated user with access to the database to execute commands on the underlying host system. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends mitigations for products where fixes are not or not yet available. The following versions of Siemens WinCC are affected: SIMATIC WinCC V7.5 vers:all/* (CVE-2026-59241) SIMATIC WinCC V8.0 vers:intdot/<8.0.0.…
CVE-2026-59241 -
CISA ICS Advisories
Siemens RUGGEDCOM CROSSBOW
View CSAF Summary RUGGEDCOM CROSSBOW contains multiple vulnerabilities that could allow an attacker to execute arbitrary SQL commands on the underlying database, retrieve sensitive administrative credentials, escalate privileges, and perform unauthorized operations such as modifying system configurations or causing a denial of service. Siemens has released a new version for RUGGEDCOM CROSSBOW and recommends to update to the latest version. The following versions of Siemens RUGGEDCOM CROSSBOW are affected: RUGGEDCOM CROSSBOW vers:intdot/<6.0 (CVE-2026-89196, CVE-2026-89197, CVE-2026-89198, CVE…
CVE-2026-89196, CVE-2026-89197, CVE-2026-89198 -
CISA ICS Advisories
Siemens Industrial Edge Device Kit
View CSAF Summary Users of Industrial Edge Devices are advised to consult the respective Security Advisories for their devices (for Siemens Industrial Edge devices see Additional Information). Industrial Edge Device Kit contains multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are not, or not yet available. The following versio…
-
CISA ICS Advisories
Siemens APOGEE, TALON and Desigo PXC/PXM Products
View CSAF Summary The products listed below contain multiple vulnerabilities that could allow an attacker to cause a denial of service and potentially impact the availability of the affected device. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens APOGEE, TALON and Desigo PXC/PXM Products are affected: APOGEE MBC (PPC) (BACnet) vers:all/* (CVE-2026-102073, CVE-2026-102074, CVE-2026-102075, CVE-2026-1020…
CVE-2026-102073, CVE-2026-102074, CVE-2026-102075 +1 -
CISA ICS Advisories
Siemens SIMATIC IPCs
View CSAF Summary The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens SIMATIC IPCs are affected: SIMATIC IPC BX-21A vers:intdot/<31.01.13 (CVE-2026-72895) SIMATIC IPC RW-543A vers:intdot/<1.1.4 (CVE-2026-72895) SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G vers:intdo…
CVE-2026-72895 -
CISA ICS Advisories
Siemens PSS(R)SINCAL
View CSAF Summary PSS(R)SINCAL uses WibuKey third-party product that contains an out-of-bounds write vulnerability. An attacker could exploit this vulnerability to cause a system crash, resulting in a denial-of-service condition. This affects PSS SINCAL only when configured to use the legacy WibuKey dongle license type. Siemens is actively preparing updates and recommends applicable mitigations for products where patches are currently unavailable. The following versions of Siemens PSS(R)SINCAL are affected: PSS(R)SINCAL V21.5 vers:all/* (CVE-2026-84854) PSS(R)SINCAL V22.0 vers:all/* (CVE-2026…
CVE-2026-84854 -
CISA ICS Advisories
Siemens SENTRON 3NA COM Fuse
View CSAF Summary SENTRON 3NA COM Fuse contains a Denial-of-Service vulnerability. Improper handling of a network management message could allow an attacker to trigger a denial-of-service (DoS) condition. Successful exploitation may require the affected network to be re-established to restore normal operation. The following versions of Siemens SENTRON 3NA COM Fuse are affected: SENTRON 3NA COM Fuse vers:intdot/<5.2 (CVE-2024-7322) CVSS Vendor Equipment v3 5.8 Siemens SENTRON 3NA COM Fuse 1 Vulnerability Improper Verification of Source of a Communication Channel Background Critical Infrastruct…
CVE-2024-7322 -
CISA ICS Advisories
Siemens Capital Embedded AR Classic
View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded AR Classic are affected: Capital Embedded AR Classic 431-422 vers:all/* (CVE-2026-89208) Capital Embe…
CVE-2026-89208 -
CISA ICS Advisories
Siemens Software Center
View CSAF Summary The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about current known active exploitation and how to detect it. The following versions of Siemens Software…
-
CISA ICS Advisories
Siemens Industrial Edge App Publisher
View CSAF Summary The Industrial Edge App Publisher contains a vulnerability chain involving improper certificate validation and the rendering of unescaped data from backend responses. These issues can be combined to allow an attacker on the network to impersonate the management server and execute arbitrary code (RCE) on the local machine through Node.js integration. Siemens has released an update for the Industrial Edge App Publisher and recommends to update to the latest version. The following versions of Siemens Industrial Edge App Publisher are affected: Industrial Edge App Publisher vers…
-
CISA ICS Advisories
Kiloview E3 NDI Encoder
View CSAF Summary Successful exploitation of this these vulnerabilities could allow an attacker to fully compromise the device. The following versions of Kiloview E3 NDI Encoder are affected: E3 Firmware <1.30 (CVE-2026-109122, CVE-2026-111100, CVE-2026-96616, CVE-2026-105265, CVE-2026-110491, CVE-2026-107861, CVE-2026-110243, CVE-2026-92450, CVE-2026-110825) CVSS Vendor Equipment v3 9.9 Kiloview E3 Firmware 6 Vulnerabilities Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Missing Authentication for Critical Function, Insufficient Session Expiration…
CVE-2026-109122, CVE-2026-111100, CVE-2026-96616 +6 -
CISA ICS Advisories
Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP
View CSAF Summary Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.7 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP are affected: SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) vers:intdot/>=3.1.7 SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) vers:intdot/>=3.1.7 SIMATIC S7-1500 CPU 1518F-4 PN/D…
-
CISA ICS Advisories
HMS Networks PEAK-System PCAN Windows drivers
View CSAF Summary Successful exploitation of these vulnerabilities could crash the Windows kernel. The following versions of HMS Networks PEAK-System PCAN Windows drivers are affected: PEAK-System Device Driver Setup <=5.1.2.1151 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) PCAN Windows CAN device drivers <=5.1.2 (CVE-2026-109576, CVE-2026-101103, CVE-2026-94188, CVE-2026-103672, CVE-2026-110322, CVE-2026-105960) CVSS Vendor Equipment v3 7.1 HMS Networks PEAK-System Device Driver Setup 5 Vulnerabilities Out-of-bounds Write, Buffer Copy…
CVE-2026-109576, CVE-2026-101103, CVE-2026-94188 +3 -
CISA ICS Advisories
Moxa AIG-302 ThingsPro Edge
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to obtain and disclose sensitive information. The following versions of Moxa AIG-302 ThingsPro Edge are affected: Moxa AIG-302 ThingsPro Edge firmware <=1.4.0 (CVE-2026-109812, CVE-2026-109813) CVSS Vendor Equipment v3 8.1 Moxa Moxa AIG-302 ThingsPro Edge firmware 2 Vulnerabilities Missing Authorization, Use of Hard-coded Cryptographic Key Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Water and Wastewater Systems Countries/Areas Deployed: Worldwide Company Headquarters Loca…
CVE-2026-109812, CVE-2026-109813 -
CISA ICS Advisories
Hitachi Energy MicroSCADA X SYS600 Product
View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect MicroSCADA X SYS600 product versions listed in this document. These vulnerabilities can be exploited to carry out various attacks on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy MicroSCADA X SYS600 Product are affected: MicroSCADA X SYS600 vers:MicroSCADA_X_SYS600/<=10.7, 10.8 (CVE-2026-9852, CVE-2026-9853, CVE-2026-9854, CVE-2026-9853) CVSS Vendor Equipment v3 7.8 Hitachi Energy MicroSCADA X SYS600 2 Vul…
CVE-2026-9852, CVE-2026-9853, CVE-2026-9854 -
CISA ICS Advisories
Hitachi Energy RTU500 Product
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect RTU500 product versions listed in this document. These vulnerabilities if exploited can have impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy RTU500 Product are affected: RTU500 series CMU Firmware vers:RTU500_series_CMU_Firmware/>=13.5.1|<=13.5.4, vers:RTU500_series_CMU_Firmware/>=13.6.1|<=13.6.3, vers:RTU500_series_CMU_Firmware/>=13.7.1|<=13.7.8, vers:RTU500_s…
-
CISA ICS Advisories
WAGO OS Linux
View CSAF Summary Two vulnerabilities in the Web-Based Management (WBM) interface of WAGO CC100, PFC100 G2, PFC200 G2, TP600, Edge Controller and WP400 devices allow an authenticated low-privileged user to bypass intended privilege boundaries. The issues affect both the routing configuration functionality and the authorization model for PROFIBUS configuration management. The following versions of WAGO OS Linux are affected: WAGO Firmware (vers:semver/>=1.0.0|<4.10.0) installed on WAGO Hardware 0751-9x01 vers:all/* (CVE-2026-80466, CVE-2026-88850) WAGO Firmware (vers:semver/>=1.0.0|<4.10.0) in…
CVE-2026-80466, CVE-2026-88850 -
CISA ICS Advisories
Eclipse Foundation Eclipse Milo
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to delete protected data, recover user credentials and impersonate legitimate users, or cause the server to stop responding to all clients. The following versions of Eclipse Foundation Eclipse Milo are affected: Eclipse Milo >=0.6.0|<=1.1.4 (CVE-2026-63252, CVE-2026-63248, CVE-2026-60007) Eclipse Milo >=1.0.0|<=1.1.4 (CVE-2026-62927, CVE-2026-58080, CVE-2026-61387) CVSS Vendor Equipment v3 8.2 Eclipse Foundation Eclipse Milo 5 Vulnerabilities Incorrect Authorization, Missing Release of Memory after Effe…
CVE-2026-63252, CVE-2026-63248, CVE-2026-60007 +3 -
CISA ICS Advisories
Guangzhou Juan IoT Technology EseeCloud
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain control over affected IP cameras. The following versions of Guangzhou Juan IoT Technology EseeCloud are affected: EseeCloud App <=4.9.6 (CVE-2026-107617, CVE-2026-97858, CVE-2026-105664) EseeCloud Firmware <=4.9.86.0 (CVE-2026-107617, CVE-2026-97858, CVE-2026-105664) CVSS Vendor Equipment v3 9.8 Guangzhou Juan IoT Technology Co., Ltd. EseeCloud App 3 Vulnerabilities Use of Hard-coded Credentials, Improperly Controlled Modification of Dynamically-Determined Object Attributes, Observable Response…
CVE-2026-107617, CVE-2026-97858, CVE-2026-105664 -
CISA ICS Advisories
CISA Malcolm
View CSAF Summary The following versions of CISA Malcolm are affected: Malcolm <=v26.07.1 (CVE-2026-107336, CVE-2026-107361, CVE-2026-107337, CVE-2026-107335, CVE-2026-107334) Malcolm <=v26.08.0 (CVE-2026-107333, CVE-2026-107362) CVSS Vendor Equipment v3 8.1 CISA Malcolm 6 Vulnerabilities Authentication Bypass by Spoofing, Incorrect Authorization, Server-Side Request Forgery (SSRF), Authentication Bypass Using an Alternate Path or Channel, Cross-Site Request Forgery (CSRF), Improper Handling of Highly Compressed Data (Data Amplification) Background Critical Infrastructure Sectors: Energy, Inf…
CVE-2026-107336, CVE-2026-107361, CVE-2026-107337 +4 -
CISA ICS Advisories
Inductive Automation Ignition Software
View CSAF Summary Successful exploitation of this vulnerability could allow an authenticated low-level user to escalate their privileges to a higher level. The following versions of Inductive Automation Ignition Software are affected: Ignition >=8.1.0|<=8.1.54 (CVE-2026-92817) Ignition >=8.3.0|<=8.3.8 (CVE-2026-92817) CVSS Vendor Equipment v3 8.8 Inductive Automation Ignition 1 Vulnerability Incorrect Authorization Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States…
CVE-2026-92817 -
CISA ICS Advisories
Swann Communications SWIFI-SE2KIC
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to view video information without authentication. The following versions of Swann Communications SWIFI-SE2KIC are affected: SWIFI-SE2KIC firmware <=2.0.22 (CVE-2026-107605, CVE-2026-107606, CVE-2026-107607) CVSS Vendor Equipment v3 6.2 Swann Communications SWIFI-SE2KIC firmware 1 Vulnerability Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Australia Vulnerabilities Expand Al…
CVE-2026-107605, CVE-2026-107606, CVE-2026-107607 -
CISA ICS Advisories
Red Lion Controls N-Tron 700 Series (Update A)
View CSAF Summary Successful exploitation of these vulnerabilities could allow a malicious user to access the device and gain administrative access. This access would allow the user to view, edit, and upload configuration files. Further, a malicious user can cause the switch to reboot by navigating to a specific URL on the device. This action can be scripted on the malicious user's local machine to cause continuous rebooting of the switch. The following versions of Red Lion Controls N-Tron 700 Series are affected: 700 Series <=Firmware_3.11.0 (CVE-2026-32645, CVE-2026-39460, CVE-2026-28745, C…
CVE-2026-32645, CVE-2026-39460, CVE-2026-28745 -
CISA ICS Advisories
Grid Protection Alliance openPDC and openHistorian
View CSAF Summary The following versions of Grid Protection Alliance openPDC and openHistorian are affected: openPDC <2.9.477, <2.9.482 (CVE-2026-104629, CVE-2026-100730, CVE-2026-105281, CVE-2026-85479, CVE-2026-101022) openPDC (Docker image) <2.9.477, <2.9.482 (CVE-2026-104629, CVE-2026-100730, CVE-2026-105281, CVE-2026-85479, CVE-2026-101022, CVE-2026-105278) openHistorian <2.8.580, <2.8.585 (CVE-2026-104629, CVE-2026-100730, CVE-2026-105281, CVE-2026-85479, CVE-2026-101022) CVSS Vendor Equipment v3 9.8 Grid Protection Alliance openPDC 5 Vulnerabilities Deserialization of Untrusted Data, M…
CVE-2026-104629, CVE-2026-100730, CVE-2026-105281 +3 -
CISA ICS Advisories
Satel Netco Design
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary scripts in a user's browser, consume excessive system resources, enumerate files, create or modify files, and potentially execute arbitrary code. The following versions of Satel Netco Design are affected: Satel Netco Design CVSS Vendor Equipment v3 8.8 Satel Satel Netco Design 3 Vulnerabilities Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Inefficient Regular Expression Complexity, Relative Path Traversal Background Critical Infrastructure Sec…
-
CISA ICS Advisories
Johnson Controls EasyIO FG
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain full unauthorized access to the device. The following versions of Johnson Controls EasyIO FG are affected: EasyIO FG firmware <=2.0b52 (CVE-2026-27872, CVE-2026-27873) CVSS Vendor Equipment v3 7.7 Johnson Controls EasyIO FG firmware 2 Vulnerabilities Use of Hard-coded Credentials, Improper Privilege Management Background Critical Infrastructure Sectors: Critical Manufacturing, Commercial Facilities, Government Services and Facilities, Transportation Systems, Energy Countries/Areas Deployed: Worl…
CVE-2026-27872, CVE-2026-27873 -
CISA ICS Advisories
Savannah lwIP SMTP client
View CSAF Summary Successful exploitation of this vulnerability could crash the device being accessed; a buffer overflow condition may allow remote code execution. The following versions of Savannah lwIP SMTP client are affected: lwIP SMTP client 2.2.1 (CVE-2026-15340) CVSS Vendor Equipment v3 9.8 Savannah lwIP SMTP client 1 Vulnerability Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') Background Critical Infrastructure Sectors: Energy, Water and Wastewater Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Sweden Vulnerabilities CVE-2026-15340 l…
CVE-2026-15340 -
CISA ICS Advisories
Hitachi Energy Asset Suite
View CSAF Summary Hitachi Energy is aware of unauthenticated servlet access vulnerabilities that affect Asset Suite product versions listed in this document. These vulnerabilities can be exploited to potentially cause confidentiality, integrity and availability impact on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy Asset Suite are affected: Asset Suite vers:Asset_Suite/<=9.9.0 (CVE-2026-7395, CVE-2026-11796) CVSS Vendor Equipment v3 8.1 Hitachi Energy Asset Suite 1 Vulnerability Missin…
CVE-2026-7395, CVE-2026-11796 -
CISA ICS Advisories
Hitachi Energy SOI
View CSAF Summary Hitachi Energy is aware of RCE (Remote Code Execution) vulnerability in Apache ActiveMQ component of SOI product versions listed in this document. These vulnerabilities can be exploited to carry out various attacks affecting confidentiality, integrity, and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy SOI are affected: SOI vers:SOI/>=2.0.0|<=2.2.0 (CVE-2026-34197) CVSS Vendor Equipment v3 8.8 Hitachi Energy SOI 1 Vulnerability Improper Control of Genera…
CVE-2026-34197 -
CISA ICS Advisories
Hitachi Energy REB500
View CSAF Summary Hitachi Energy is aware of open-source software vulnerabilities that affect REB500 product versions listed in this document. These vulnerabilities can be exploited to carry out Denial of Service (DoS) attack on the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The following versions of Hitachi Energy REB500 are affected: REB500 vers:REB500/<=8.3.3.1 (CVE-2024-8176, CVE-2025-59375) CVSS Vendor Equipment v3 6.5 Hitachi Energy REB500 2 Vulnerabilities Uncontrolled Recursion, Allocation of Resources Without Limits or…
CVE-2024-8176, CVE-2025-59375 -
CISA ICS Advisories
Hitachi Energy RTU500
View CSAF Summary Hitachi Energy is publishing this cybersecurity advisory in response to the security findings reported by Dragos affecting end-of-life RTU500 CMU firmware version 9.x. The reported findings are associated with legacy RTU500 firmware versions that were developed according to the cybersecurity requirements, threat landscape, and industry practices that existed at the time of their release. As cybersecurity threats and security expectations have evolved, these end-of-life versions no longer incorporate many of the security controls and hardening measures that are standard in mo…
-
CISA ICS Advisories
Armatura LLC Armatura One
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to gain unauthorized access to the database, execute arbitrary code on the host with the highest level of privilege, or gain control of the physical access-control system. The following versions of Armatura LLC Armatura One are affected: Armatura One <4.7.2 (CVE-2023-46604, CVE-2026-94591, CVE-2026-94592, CVE-2026-94593, CVE-2026-94594) Armatura One (USA) <4.6.1 (CVE-2023-46604, CVE-2026-94591, CVE-2026-94592, CVE-2026-94593, CVE-2026-94594) CVSS Vendor Equipment Vulnerabilities v3 9.8 Armatura LLC Arma…
CVE-2023-46604, CVE-2026-94591, CVE-2026-94592 +2 -
CISA ICS Advisories
Monta monta.app
View CSAF Summary Successful exploitation of these vulnerabilities could enable attackers to gain unauthorized administrative control over vulnerable charging stations or disrupt charging services through denial-of-service attacks. The following versions of Monta monta.app are affected: monta.app vers:all/* (CVE-2026-95102, CVE-2026-97363, CVE-2026-97212, CVE-2026-93474) CVSS Vendor Equipment Vulnerabilities v3 9.4 Monta Monta monta.app Missing Authentication for Critical Function, Improper Restriction of Excessive Authentication Attempts, Insufficient Session Expiration, Insufficiently Prote…
CVE-2026-95102, CVE-2026-97363, CVE-2026-97212 +1 -
CISA ICS Advisories
ABB Protection and Control IED Manager PCM600
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges or overwrite files. The following versions of ABB Protection and Control IED Manager PCM600 are affected: Protection and Control IED Manager PCM600 <=2.14 (CVE-2026-15952, CVE-2026-15953) CVSS Vendor Equipment Vulnerabilities v3 6.4 ABB ABB Protection and Control IED Manager PCM600 Incorrect Permission Assignment for Critical Resource, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Energy Countries/Areas D…
CVE-2026-15952, CVE-2026-15953 -
CISA ICS Advisories
Johnson Controls EasyIO Neo Series EC and CW Controllers
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to gain access to sensitive information that could be used to conduct further attacks against the system. The following versions of Johnson Controls EasyIO Neo Series EC and CW Controllers are affected: EasyIO Neo Series EC Controllers V3.3b63 (CVE-2026-64892) EasyIO Neo Series EC Controllers V3.3b62 (CVE-2026-64892) EasyIO Neo Series CW Controllers V3.3b25 (CVE-2026-64892) EasyIO Neo Series CW Controllers V3.3b24 (CVE-2026-64892) CVSS Vendor Equipment Vulnerabilities v3 3.5 Johnson Controls Johnson Contro…
CVE-2026-64892 -
CISA ICS Advisories
Johnson Controls EasyIO Neo Series EC and CW Controllers
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker tointercept and read sensitive information, including credentials andsession data. The following versions of Johnson Controls EasyIO Neo Series EC and CW Controllers are affected: EasyIO Neo Series EC Controllers V3.3b62 (CVE-2026-64893) EasyIO Neo Series EC Controllers V3.3b63 (CVE-2026-64893) EasyIO Neo Series CW Controllers V3.3b24 (CVE-2026-64893) EasyIO Neo Series CW Controllers V3.3b25 (CVE-2026-64893) CVSS Vendor Equipment Vulnerabilities v3 5.4 Johnson Controls Johnson Controls EasyIO Neo Series EC…
CVE-2026-64893 -
CISA ICS Advisories
Meari IoT Cloud Platform OpenAPI Service
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to manipulate device configurations, trigger unauthorized behaviors, and access sensitive information such as device credentials, owner details, and network data without proper authorization. The following versions of Meari IoT Cloud Platform OpenAPI Service are affected: IoT Cloud Platform OpenAPI Service vers:all/* (CVE-2026-101104, CVE-2026-96613) CVSS Vendor Equipment Vulnerabilities v3 7.7 Meari Meari IoT Cloud Platform OpenAPI Service Missing Authorization Background Critical Infrastructure Sectors:…
CVE-2026-101104, CVE-2026-96613 -
CISA ICS Advisories
CISA Malcolm
View CSAF Summary The following versions of CISA Malcolm are affected: Malcolm CVSS Vendor Equipment Vulnerabilities v3 8.8 CISA CISA Malcolm Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Server-Side Request Forgery (SSRF), Authentication Bypass by Spoofing, Missing Authorization, Missing Authentication for Critical Function, Incorrect Authorization, Use of Default Credentials, Improp…
-
CISA ICS Advisories
Viidure Dashcam Android Application
View CSAF Summary Successful exploitation of these vulnerabilities could allow attackers to access, modify, or delete sensitive user data and critical system files, potentially compromising the operation of the entire platform. The following versions of Viidure Dashcam Android Application are affected: Dashcam Android Application <=3.3.1.260403 (CVE-2026-94204, CVE-2026-96587) CVSS Vendor Equipment Vulnerabilities v3 10 Viidure Viidure Dashcam Android Application Incorrect Permission Assignment for Critical Resource, Use of Hard-coded Credentials Background Critical Infrastructure Sectors: Tr…
CVE-2026-94204, CVE-2026-96587 -
CISA ICS Advisories
MikroTik RouterOS
View CSAF Summary Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution or cause a denial of service. The following versions of MikroTik RouterOS are affected: RouterOS <7.24 (CVE-2026-84411) CVSS Vendor Equipment Vulnerabilities v3 9.8 MikroTik MikroTik RouterOS Integer Underflow (Wrap or Wraparound) Background Critical Infrastructure Sectors: Communications, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: Latvia Vulnerabilities Expand All + CVE-2026-84411 The web management service in affected RouterO…
CVE-2026-84411 -
CISA ICS Advisories
Anjvision YSSD-RTMP-H5
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access sensitive information, access user accounts, execute OS-level commands, or take full control over the device. The following versions of Anjvision YSSD-RTMP-H5 are affected: YSSD-RTMP-H5 firmware 3.3.2.4_build_2024-12-26 (CVE-2026-100291, CVE-2026-100292, CVE-2026-100293, CVE-2026-100294, CVE-2026-100295, CVE-2026-100296, CVE-2026-100297, CVE-2026-100298, CVE-2026-100299) CVSS Vendor Equipment Vulnerabilities v3 9.8 Anjvision Anjvision YSSD-RTMP-H5 Initialization of a Resource with an Insecure…
CVE-2026-100291, CVE-2026-100292, CVE-2026-100293 +6 -
CISA ICS Advisories
VIVOTEK Camera Firmware
View CSAF Summary Successful exploitation of this vulnerability may allow attackers to achieve remote command execution on affected devices, potentially with root privileges, leading to full compromise of the camera system. The following versions of VIVOTEK Camera Firmware are affected: V Series model_FD9187 (CVE-2026-22755) V Series model_FD9189 (CVE-2026-22755) V Series model_FD9365 (CVE-2026-22755) V Series model_FD9387 (CVE-2026-22755) V Series model_FD9389 (CVE-2026-22755) V Series model_FD9391 (CVE-2026-22755) C Series model_FE9180 (CVE-2026-22755) V Series model_FE9191 (CVE-2026-22755)…
CVE-2026-22755