RHEL-09-252010 RHEL 9 must have the chrony package installed.

DISA STIG library V2R10
All changes in this version
first version loaded CAT II

Maps to AU-8(1), SC-45(1) via CCI-004923, CCI-001891

Title

RHEL 9 must have the chrony package installed.

Control

Verify that RHEL 9 has the chrony package installed with the following command: $ dnf list --installed chrony Example output: chrony.x86_64 4.1-3.el9 If the "chrony" package is not installed, this is a finding.

Discussion

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Sources outside the configured acceptable allowance (drift) may be inaccurate.

Related controls

CCI-001891, CCI-004923

Fix

The chrony package can be installed with the following command: $ sudo dnf install chrony