9.1 Scope

NIST PIV and digital identity SP 800-76-2 against SP 800-76-1
All changes in this version
added 9 Common header for PIV biometric data part of 9

Title changed

Before · SP 800-76-1

After · SP 800-76-2

Scope

Control changed

Before · SP 800-76-1

After · SP 800-76-2

All PIV biometric data shall be embedded in a data structure conforming to Common Biometric Exchange Formats Framework [CBEFF]. This specifies that all biometric data shall be digitally signed and uniformly encapsulated. This covers the following static data: ― The PIV Card fingerprints mandated by [FIPS]; ― The PIV Card facial image mandated by [FIPS]; ― Any other biometric data that agencies elect to place on PIV Cards (e.g.,iris); ― Any biometric records that agencies elect to retain (including purely proprietary, or derivative, elements); ― Any biometric data retained by, or for, agencies or Registration Authorities. There are three pieces of data that are exempt: ― The [EBTS] data of Section 3.4 sent for background checks 20 ; ― The OCC data of Section 5.4 that is stored on the PIV Card 21 ; For the relevant data above, integrity shall be protected by pre-pending the data with a CBEFF header and appending with a signature stored in the CBEFF signature block as depicted in the linear structure of Table 13 .

Table 13 − CBEFF concatenation structure CBEFF_HEADER CBEFF_BIOMETRIC_RECORD CBEFF_SIGNATURE_BLOCK Section 9.2 Sections 3.2.2 , 3.3 , 6.3 . 6.4 and 7.2 Section 9.3 INCITS 398 5.2.1 INCITS 398 5.2.2 INCITS 398 5.2.3