BaselineWatch
Desk

4.9 Self-Tests

NIST platform security: roots of trust, firmware and secure enclaves FIPS 140-2
All changes in this version
first version loaded 4 SECURITY REQUIREMENTS part of 4

Title

Self-Tests

Control

A cryptographic module shall perform power-up self-tests and conditional self-tests to ensure that the module is functioning properly. Power-up self-tests shall be performed when the cryptographic module is powered up. Conditional self-tests shall be performed when an applicable security function or operation is invoked (i.e., security functions for which self-tests are required). A cryptographic module may perform other power-up or conditional self-tests in addition to the tests specified in this standard.

If a cryptographic module fails a self-test, the module shall enter an error state and output an error indicator via the status output interface. The cryptographic module shall not perform any cryptographic operations while in an error state. All data output via the data output interface shall be inhibited when an error state exists. Documentation shall specify:

the self-tests performed by a cryptographic module, including power-up and conditional tests, •

the error states that a cryptographic module can enter when a self-test fails, and