4.5.5.1 Environmental Failure Protection Features (Alternative 1)
All changes in this version
Title changed
Before · FIPS 140-2
Environmental Failure Protection Features (Alternative 1)
After · FIPS 140-3
Environmental Failure Protection Features (Alternative 1)
Control changed
Before · FIPS 140-2
Environmental failure protection (EFP) features shall protect a cryptographic module against unusual environmental conditions or fluctuations (accidental or induced) outside of the module's normal operating range that can compromise the security of the module. In particular, the cryptographic module shall monitor and correctly respond to fluctuations in the operating temperature and voltage outside of the specified normal operating ranges.
The EFP features shall involve electronic circuitry or devices that continuously measure the operating temperature and voltage of a cryptographic module. If the temperature or voltage fall outside of the cryptographic module's normal operating range, the protection circuitry shall either (1) shutdown the module to prevent further operation or (2) immediately zeroize all plaintext secret and private cryptographic keys and CSPs.
Documentation shall specify the normal operating ranges of a cryptographic module and the environmental failure protection features employed by the module.
After · FIPS 140-3
Environmental failure protection (EFP) features shall protect a cryptographic module against unusual environmental conditions or fluctuations (accidental or induced) outside of the module's normal operating range that can compromise the security of the module. In particular, the cryptographic module shall monitor and correctly respond to fluctuations in the operating temperature and voltage outside of the specified normal operating ranges.
The EFP features shall involve electronic circuitry or devices that continuously measure the operating temperature and voltage of a cryptographic module. If the temperature or voltage fall outside of the cryptographic module's normal operating range, the protection circuitry shall either (1) shutdown the module to prevent further operation or (2) immediately zeroize all plaintext secret and private cryptographic keys and CSPs.
Documentation shall specify the normal operating ranges of a cryptographic module and the environmental failure protection features employed by the module.