BaselineWatch
Desk

SC-41 Port and I/O Device Access

NIST SP 800-53 (controls) 5.2.0 against 5.2.0
All changes in this version
unchanged SC

Title

Port and I/O Device Access

Control

[Selection: physically; logically] disable or remove [Assignment: connection ports or input/output devices] on the following systems or system components: [Assignment: systems or system components].

Discussion

Connection ports include Universal Serial Bus (USB), Thunderbolt, and Firewire (IEEE 1394). Input/output (I/O) devices include compact disc and digital versatile disc drives. Disabling or removing such connection ports and I/O devices helps prevent the exfiltration of information from systems and the introduction of malicious code from those ports or devices. Physically disabling or removing ports and/or devices is the stronger action.

Parameters

sc-41_odp.01: connection ports or input/output devices
sc-41_odp.02: [physically; logically]
sc-41_odp.03: systems or system components

Related controls

ac-20, mp-7

Assessment objective

SC-41 [Assignment: connection ports or input/output devices] are [Selection: physically; logically] disabled or removed on [Assignment: systems or system components].

STIG rules that implement this control 3

Google Android 16 COBO Y26M10

Google Android 17 COBO Y26M06

Samsung Android 16 COBO Y26M10