SI-07(05) Automated Response to Integrity Violations

NIST SP 800-53 (controls) 5.1.1+u4
All changes in this version
first version loaded SI High baseline part of SI-7

Title

Automated Response to Integrity Violations

Control

Automatically [Selection (one or more): shut down the system; restart the system; implement {{ insert: param, si-07.05_odp.02 }} ] when integrity violations are discovered.

Discussion

Organizations may define different integrity-checking responses by type of information, specific information, or a combination of both. Types of information include firmware, software, and user data. Specific information includes boot firmware for certain types of machines. The automatic implementation of controls within organizational systems includes reversing the changes, halting the system, or triggering audit alerts when unauthorized modifications to critical security files occur.

Parameters

si-07.05_odp.01: [shut down the system; restart the system; implement {{ insert: param, si-07.05_odp.02 }} ]
si-07.05_odp.02: controls

Assessment objective

SI-07(05) [Selection (one or more): shut down the system; restart the system; implement {{ insert: param, si-07.05_odp.02 }} ] are automatically performed when integrity violations are discovered.

STIG rules that implement this control 0