7.3 high exploit ×5 SSVC exploitation: poc Modified

The c_rehash script does not properly sanitise shell metacharacters to prevent command injection. This script is distributed by some operating systems in a manner where it is automatically executed. On such operating systems, an attacker could execute arbitrary commands with the privileges of the script. Use of the c_rehash script is considered obsolete and should be replaced by the OpenSSL rehash command line tool. Fixed in OpenSSL 3.0.3 (Affected 3.0.0,3.0.1,3.0.2). Fixed in OpenSSL 1.1.1o (Affected 1.1.1-1.1.1n). Fixed in OpenSSL 1.0.2ze (Affected 1.0.2-1.0.2zd).

Fix

Public exploits 5

Each line links to the index that lists it, never to exploit code. Exploit-DB's "verified" and a Metasploit rank of good or better count as verified; a PoC-in-GitHub entry is a repository's claim.

Patch, vendor advisory and mitigation references on NVD 2

Every line above is quoted from NVD, CISA, Microsoft, the vendor's own advisory or DISA; nothing is generated.

Change history 1

  1. First seenCVSS 7.3 · siemens, openssl, debianNVD modified 2026-10-14 13:17

Affected (CPE criteria) 40

  • cpe:2.3:a:siemens:brownfield_connectivity_gateway:*:*:*:*:*:*:*:*
  • cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*
  • cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*
  • cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*
  • cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*
  • cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vsphere:*:*
  • cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:windows:*:*
  • cpe:2.3:a:netapp:clustered_data_ontap:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:clustered_data_ontap_antivirus_connector:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:smi-s_provider:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:snapmanager:-:*:*:*:*:hyper-v:*:*
  • cpe:2.3:a:netapp:solidfire\,_enterprise_sds_\&_hci_storage_node:-:*:*:*:*:*:*:*
  • cpe:2.3:a:netapp:solidfire_\&_hci_management_node:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a700s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h300s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h500s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h700s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h300e_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h500e_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h700e_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:h410s_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_8300_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas_8300_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_8700_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas_8700_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_a400_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fabric-attached_storage_a400_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:a250_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:aff_500f_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:o:netapp:fas_500f_firmware:-:*:*:*:*:*:*:*
  • cpe:2.3:a:oracle:enterprise_manager_ops_center:12.4.0.0:*:*:*:*:*:*:*
  • cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*
  • cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*
  • cpe:2.3:o:fedoraproject:fedora:35:*:*:*:*:*:*:*
  • cpe:2.3:o:fedoraproject:fedora:36:*:*:*:*:*:*:*

References 35