BaselineWatch
Desk

CVE-2025-34202

8.7 high SSVC exploitation: poc Modified

Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to 25.2.169 and Application prior to 25.2.1518 (VA and SaaS deployments) expose Docker internal networks in a way that allows an attacker on the same external L2 segment — or an attacker able to add routes using the appliance as a gateway — to reach container IPs directly. This grants access to internal services (HTTP APIs, Redis, MySQL, etc.) that are intended to be isolated inside the container network. Many of those services are accessible without authentication or are vulnerable to known exploitation chains. As a result, compromise of a single reachable endpoint or basic network access can enable lateral movement, remote code execution, data exfiltration, and full system compromise. This vulnerability has been identified by the vendor as: V-2025-003 — Insecure Access to Docker Instance from WAN.

Fix

Patch, vendor advisory and mitigation references on NVD 2

Every line above is quoted from NVD, CISA, Microsoft, the vendor's own advisory or DISA; nothing is generated.

Change history 1

  1. First seenCVSS 8.7 · vasionNVD modified 2026-10-18 21:10

Affected (CPE criteria) 2

  • cpe:2.3:a:vasion:virtual_appliance_application:*:*:*:*:*:*:*:*
  • cpe:2.3:a:vasion:virtual_appliance_host:*:*:*:*:*:*:*:*

References 4