CVE-2026-12851

9.1 critical SSVC exploitation: none Deferred

Multiple OS command injection vulnerabilities exist in the libNetSetObj.so functionality of GeoVision GV-I/O Box 4E 2.09. A specially crafted network packet can lead to command execution. An attacker can send a network request to trigger this vulnerability. `libNetSetObj.so` is an internal library used by various binaries on the device to configure the network stack (start and stop various services, configure IP, Netmask, gateway, dns, etc.) #### CNetSetObj::m_F_n_Set_DNS_Addr command injection The following function can take up to two addresses, performs no sanitization and then calls `system`. This is a classic command injection vulnerability. The function is reachable from both the network-exposed `DVRSearch` service and the `Network.cgi` endpoint. int __fastcall CNetSetObj::m_F_n_Set_DNS_Addr(CNetSetObj *this, char *dns1, char *dns2) { int result; // r0 char v5[80]; // [sp+0h] [bp-50h] BYREF if ( !dns1 ) result = 0; if ( dns1 ) { sprintf(v5, "/bin/echo nameserver %s > /etc/resolv.conf", dns1); // attacker controlled dns1 field system(v5); if ( dns2 ) { sprintf(v5, "/bin/echo nameserver %s >> /etc/resolv.conf", dns2); system(v5); } return 1; } return result;

Fix

Nothing published yet: no patch, vendor advisory or mitigation reference on NVD, no vendor advisory in the News for this CVE, not in CISA's KEV, no fixed package version. BaselineWatch does not guess at one.

Change history 1

  1. First seenCVSS 9.1NVD modified 2026-10-25 23:10

Affected (CPE criteria) 0

NVD has not attached CPE configurations yet.

References 2