BaselineWatch
1196 requirements
Desk

NIST SP 800-53 (controls) 5.2.0

AllACATAUCACMCPIAIRMAMPPEPLPMPSPTRASASCSISR
Controls in this version
RefTitleText
PE-01 Policy and Procedures a. Develop, document, and disseminate to [Assignment: organization-defined personnel or roles]: 1. [Selection (one or more): organization-level; mission/business process-level; system-level] physical and environmental protection policy that
PE-02 Physical Access Authorizations a. Develop, approve, and maintain a list of individuals with authorized access to the facility where the system resides; b. Issue authorization credentials for facility access; c. Review the access list detailing authorized facility access
PE-02(01)
in PE-2
Access by Position or Role Authorize physical access to the facility where the system resides based on position or role.
PE-02(02)
in PE-2
Two Forms of Identification Require two forms of identification from the following forms of identification for visitor access to the facility where the system resides: [Assignment: list of acceptable forms of identification].
PE-02(03)
in PE-2
Restrict Unescorted Access Restrict unescorted access to the facility where the system resides to personnel with [Selection (one or more): security clearances for all information contained within the system; formal access authorizations for all information contained
PE-03 Physical Access Control a. Enforce physical access authorizations at [Assignment: entry and exit points] by: 1. Verifying individual access authorizations before granting access to the facility; and 2. Controlling ingress and egress to the facility using [Selectio
PE-03(01)
in PE-3
System Access Enforce physical access authorizations to the system in addition to the physical access controls for the facility at [Assignment: physical spaces].
PE-03(02)
in PE-3
Facility and Systems Perform security checks [Assignment: frequency] at the physical perimeter of the facility or system for exfiltration of information or removal of system components.
PE-03(03)
in PE-3
Continuous Guards Employ guards to control [Assignment: physical access points] to the facility where the system resides 24 hours per day, 7 days per week.
PE-03(04)
in PE-3
Lockable Casings Use lockable physical casings to protect [Assignment: system components] from unauthorized physical access.
PE-03(05)
in PE-3
Tamper Protection Employ [Assignment: anti-tamper technologies] to [Selection (one or more): detect; prevent] physical tampering or alteration of [Assignment: hardware components] within the system.
PE-03(06)
in PE-3
Facility Penetration Testing withdrawn
PE-03(07)
in PE-3
Physical Barriers Limit access using physical barriers.
PE-03(08)
in PE-3
Access Control Vestibules Employ access control vestibules at [Assignment: locations].
PE-04 Access Control for Transmission Control physical access to [Assignment: system distribution and transmission lines] within organizational facilities using [Assignment: security controls].
PE-05 Access Control for Output Devices Control physical access to output from [Assignment: output devices] to prevent unauthorized individuals from obtaining the output.
PE-05(01)
in PE-5
Access to Output by Authorized Individuals withdrawn
PE-05(02)
in PE-5
Link to Individual Identity Link individual identity to receipt of output from output devices.
PE-05(03)
in PE-5
Marking Output Devices withdrawn
PE-06 Monitoring Physical Access a. Monitor physical access to the facility where the system resides to detect and respond to physical security incidents; b. Review physical access logs [Assignment: frequency] and upon occurrence of [Assignment: events] ; and c. Coordinate
PE-06(01)
in PE-6
Intrusion Alarms and Surveillance Equipment Monitor physical access to the facility where the system resides using physical intrusion alarms and surveillance equipment.
PE-06(02)
in PE-6
Automated Intrusion Recognition and Responses Recognize [Assignment: classes or types of intrusions] and initiate [Assignment: response actions] using [Assignment: automated mechanisms].
PE-06(03)
in PE-6
Video Surveillance (a) Employ video surveillance of [Assignment: operational areas]; (b) Review video recordings [Assignment: frequency] ; and (c) Retain video recordings for [Assignment: time period].
PE-06(04)
in PE-6
Monitoring Physical Access to Systems Monitor physical access to the system in addition to the physical access monitoring of the facility at [Assignment: physical spaces].
PE-07 Visitor Control withdrawn
PE-08 Visitor Access Records a. Maintain visitor access records to the facility where the system resides for [Assignment: time period]; b. Review visitor access records [Assignment: frequency] ; and c. Report anomalies in visitor access records to [Assignment: personne
PE-08(01)
in PE-8
Automated Records Maintenance and Review Maintain and review visitor access records using [Assignment: organization-defined automated mechanisms].
PE-08(02)
in PE-8
Physical Access Records withdrawn
PE-08(03)
in PE-8
Limit Personally Identifiable Information Elements Limit personally identifiable information contained in visitor access records to the following elements identified in the privacy risk assessment: [Assignment: elements].
PE-09 Power Equipment and Cabling Protect power equipment and power cabling for the system from damage and destruction.
PE-09(01)
in PE-9
Redundant Cabling Employ redundant power cabling paths that are physically separated by [Assignment: distance].
PE-09(02)
in PE-9
Automatic Voltage Controls Employ automatic voltage controls for [Assignment: critical system components].
PE-10 Emergency Shutoff a. Provide the capability of shutting off power to [Assignment: system or individual system components] in emergency situations; b. Place emergency shutoff switches or devices in [Assignment: location] to facilitate access for authorized pe
PE-10(01)
in PE-10
Accidental and Unauthorized Activation withdrawn
PE-11 Emergency Power Provide an uninterruptible power supply to facilitate [Selection: an orderly shutdown of the system; transition of the system to long-term alternate power] in the event of a primary power source loss.
PE-11(01)
in PE-11
Alternate Power Supply — Minimal Operational Capability Provide an alternate power supply for the system that is activated [Selection: manually; automatically] and that can maintain minimally required operational capability in the event of an extended loss of the primary power source.
PE-11(02)
in PE-11
Alternate Power Supply — Self-contained Provide an alternate power supply for the system that is activated [Selection: manually; automatically] and that is: (a) Self-contained; (b) Not reliant on external power generation; and (c) Capable of maintaining [Selection: minimally requ
PE-12 Emergency Lighting Employ and maintain automatic emergency lighting for the system that activates in the event of a power outage or disruption and that covers emergency exits and evacuation routes within the facility.
PE-12(01)
in PE-12
Essential Mission and Business Functions Provide emergency lighting for all areas within the facility supporting essential mission and business functions.
PE-13 Fire Protection Employ and maintain fire detection and suppression systems that are supported by an independent energy source.
PE-13(01)
in PE-13
Detection Systems — Automatic Activation and Notification Employ fire detection systems that activate automatically and notify [Assignment: personnel or roles] and [Assignment: emergency responders] in the event of a fire.
PE-13(02)
in PE-13
Suppression Systems — Automatic Activation and Notification (a) Employ fire suppression systems that activate automatically and notify [Assignment: personnel or roles] and [Assignment: emergency responders] ; and (b) Employ an automatic fire suppression capability when the facility is not staffed on
PE-13(03)
in PE-13
Automatic Fire Suppression withdrawn
PE-13(04)
in PE-13
Inspections Ensure that the facility undergoes [Assignment: frequency] fire protection inspections by authorized and qualified inspectors and identified deficiencies are resolved within [Assignment: time period].
PE-14 Environmental Controls a. Maintain [Selection (one or more): temperature; humidity; pressure; radiation; {{ insert: param, pe-14_odp.02 }} ] levels within the facility where the system resides at [Assignment: acceptable levels] ; and b. Monitor environmental cont
PE-14(01)
in PE-14
Automatic Controls Employ the following automatic environmental controls in the facility to prevent fluctuations potentially harmful to the system: [Assignment: automatic environmental controls].
PE-14(02)
in PE-14
Monitoring with Alarms and Notifications Employ environmental control monitoring that provides an alarm or notification of changes potentially harmful to personnel or equipment to [Assignment: personnel or roles].
PE-15 Water Damage Protection Protect the system from damage resulting from water leakage by providing master shutoff or isolation valves that are accessible, working properly, and known to key personnel.
PE-15(01)
in PE-15
Automation Support Detect the presence of water near the system and alert [Assignment: personnel or roles] using [Assignment: automated mechanisms].
PE-16 Delivery and Removal a. Authorize and control [Assignment: organization-defined types of system components] entering and exiting the facility; and b. Maintain records of the system components.
PE-17 Alternate Work Site a. Determine and document the [Assignment: alternate work sites] allowed for use by employees; b. Employ the following controls at alternate work sites: [Assignment: controls]; c. Assess the effectiveness of controls at alternate work sites
PE-18 Location of System Components Position system components within the facility to minimize potential damage from [Assignment: physical and environmental hazards] and to minimize the opportunity for unauthorized access.
PE-18(01)
in PE-18
Facility Site withdrawn
PE-19 Information Leakage Protect the system from information leakage due to electromagnetic signals emanations.
PE-19(01)
in PE-19
National Emissions Policies and Procedures Protect system components, associated data communications, and networks in accordance with national Emissions Security policies and procedures based on the security category or classification of the information.
PE-20 Asset Monitoring and Tracking Employ [Assignment: asset location technologies] to track and monitor the location and movement of [Assignment: assets] within [Assignment: controlled areas].
PE-21 Electromagnetic Pulse Protection Employ [Assignment: protective measures] against electromagnetic pulse damage for [Assignment: system and system components].
PE-22 Component Marking Mark [Assignment: system hardware components] indicating the impact level or classification level of the information permitted to be processed, stored, or transmitted by the hardware component.
PE-23 Facility Location a. Plan the location or site of the facility where the system resides considering physical and environmental hazards; and b. For existing facilities, consider the physical and environmental hazards in the organizational risk management stra

59 of 1196.