Vulnerabilities
All
My stack
Known exploited
Public exploit
Critical (9+)
Likely exploited (EPSS ≥ 50%)
Changed, 24 h
New, 24 h
Sort:
risk
modified
published
CVSS
EPSS
| CVE | CVSS | EPSS | Vendor, product | Description | Modified |
|---|---|---|---|---|---|
| CVE-2025-11523 | 2.1 low | 4.0% | tenda, ac7_firmware | A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. | 8 Oct |
| CVE-2026-4974 | 7.4 high | 1.0% | tenda, ac7_firmware | A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used. | Mon 26 Oct |
| CVE-2025-11524 | 7.4 high | 1.0% | tenda, ac7_firmware | A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used. | 8 Oct |
| CVE-2025-11525 | 7.4 high | 1.0% | tenda, ac7_firmware | A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | 8 Oct |
| CVE-2025-11526 | 7.4 high | 1.0% | tenda, ac7_firmware | A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used. | 8 Oct |
| CVE-2025-11527 | 7.4 high | 1.0% | tenda, ac7_firmware | A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. | 8 Oct |
| CVE-2025-11528 | 7.4 high | 1.0% | tenda, ac7_firmware | A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used. | 8 Oct |
| CVE-2025-11586 | 7.4 high | 1.0% | tenda, ac7_firmware | A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized. | 8 Oct |
8 of 8
Download these 8 as CSV · subscribe to this list.
EPSS scores: 2026-10-29. NVD cursor: 2026-10-29 00:22. The News page shows only notable CVEs (KEV, your stack, new criticals, EPSS over 50%, or active exploitation per SSVC); this table has all of them.