Vulnerabilities
All
My stack
Known exploited
Public exploit
Critical (9+)
Likely exploited (EPSS ≥ 50%)
Changed, 24 h
New, 24 h
Sort:
risk
modified
published
CVSS
EPSS
| CVE | CVSS | EPSS | Vendor, product | Description | Modified |
|---|---|---|---|---|---|
| CVE-2023-23946exploit ×2 | 7.5 high | 1.0% | git-scm, git | Git, a revision control system, is vulnerable to path traversal prior to versions 2.39.2, 2.38.4, 2.37.6, 2.36.5, 2.35.7, 2.34.7, 2.33.7, 2.32.6, 2.31.7, and 2.30.8. By feeding a crafted input to `git apply`, a path outside the working tree can be overwritten as the user who is running `git apply`. A fix has been prepared and will appear in v2.39.2, v2.38.4, v2.37.6, v2.36.5, v2.35.7, v2.34.7, v2.33.7, v2.32.6, v2.31.7, and v2.30.8. As a workaround, use `git apply --stat` to inspect a patch before applying; avoid applying one that creates a symbolic link and then creates a file beyond the symbolic link. | 8 Oct |
| CVE-2023-22490exploit | 5.5 medium | 1.0% | git-scm, git | Git is a revision control system. Using a specially-crafted repository, Git prior to versions 2.39.2, 2.38.4, 2.37.6, 2.36.5, 2.35.7, 2.34.7, 2.33.7, 2.32.6, 2.31.7, and 2.30.8 can be tricked into using its local clone optimization even when using a non-local transport. Though Git will abort local clones whose source `$GIT_DIR/objects` directory contains symbolic links, the `objects` directory itself may still be a symbolic link. These two may be combined to include arbitrary files based on known paths on the victim's filesystem within the malicious repository's working copy, allowing for data exfiltration in a similar manner as CVE-2022-39253. A fix has been prepared and will appear in v2.39.2 v2.38.4 v2.37.6 v2.36.5 v2.35.7 v2.34.7 v2.33.7 v2.32.6, v2.31.7 and v2.30.8. If upgrading is impractical, two short-term workarounds are available. Avoid cloning repositories from untrusted sources with `--recurse-submodules`. Instead, consider cloning repositories without recursively cloning their submodules, and instead run `git submodule update` at each layer. Before doing so, inspect each new `.gitmodules` file to ensure that it does not contain suspicious module URLs. | 8 Oct |
| CVE-2026-58399 | 8.7 high | 1.0% | no CPE yet | @acastellon/auth is an authentication control system for microservices. Versions prior to 2.3.0 appear to allow an unauthenticated authentication bypass in validateToken() through spoofable auth-user and Host request headers. The validateToken middleware contains a service-to-service bypass for auth-user: service-brother when req.get('host').startsWith(getHostName()). Both values involved in the check can be influenced by an unauthenticated HTTP client: auth-user is a request header, and Host is also client-controlled. As a result, a remote unauthenticated attacker can send a request with crafted headers and bypass token validation before the normal legacy/JWT/OIDC validation logic runs. A fix has been implemented in v2.3.0. | Sun 25 Oct |
| CVE-2023-7325 | 9.3 critical | 0.00% | no CPE yet | Anheng Mingyu Operation and Maintenance Audit and Risk Control System up to 2023-08-10 contains a server-side request forgery (SSRF) vulnerability in the xmlrpc.sock handler. The product accepts specially crafted XML-RPC requests that can be used to instruct the server to connect to internal unix socket RPC endpoints and perform privileged XML-RPC methods. An attacker able to send such requests can invoke administrative RPC methods via the unix socket interface to create arbitrary user accounts on the system, resulting in account creation and potential takeover of the bastion host. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:17.837319 UTC. | 18 Oct |
| CVE-2026-34184 | 8.8 high | 0.00% | hydrosystem.poznan, control_system | AlanWeb SCADA does not enforce authorization for some directories. This allows an unauthorized attacker to read all files in these directories and even execute some of them. Critically the attacker could run PHP scripts directly on the connected database. This issue was fixed in AlanWeb SCADA version 9.8.5 | Mon 26 Oct |
| CVE-2026-34185 | 8.7 high | 0.00% | hydrosystem.poznan, control_system | AlanWeb SCADA is vulnerable to SQL Injection across most scripts and input parameters. Because no protections are in place, an authenticated attacker can inject arbitrary SQL commands, potentially gaining full control over the database. This issue was fixed in AlanWeb SCADA version 9.8.5 | Mon 26 Oct |
| CVE-2026-8377 | 8.2 high | 0.00% | no CPE yet | Missing Authorization vulnerability in Armiya Information Technologies Ltd. Co. Access Control System (GKS) allows Collect Data from Common Resource Locations. This issue affects Access Control System (GKS): before Version 2. | Sun 25 Oct |
| CVE-2026-14468 | 7.7 high | 0.00% | no CPE yet | HashiCorp Terraform Enterprise contained an issue in its version control system (VCS) ingestion of registry modules that did not correctly enforce the intended boundary on packaged module content. This may allow an authenticated user to include files from outside the intended repository content in a module and then download them, potentially exposing sensitive files readable by the ingestion process. This vulnerability, CVE-2026-14468, is fixed in Terraform Enterprise v2.0.4 and v1.2.4. | Sun 25 Oct |
| CVE-2025-10089 | 7.7 high | 0.00% | no CPE yet | Uncontrolled Search Path Element Vulnerability in Setting and Operation Application for Lighting Control System MILCO.S Setting Application all versions, MILCO.S Setting Application (IR) all versions, MILCO.S Easy Setting Application (IR) all versions, and MILCO.S Easy Switch Application (IR) all versions allows a local attacker to execute malicious code by having installer to load a malicious DLL. However, if the signer name "Mitsubishi Electric Lighting" appears on the "Digital Signatures" tab of the properties for "MILCO.S Lighting Control.exe", the application is a fixed one. This vulnerability only affects when the installer is run, not after installation. If a user downloads directly from Mitsubishi Electric website and installs the affected product, there is no risk of malicious code being introduced. | 18 Oct |
| CVE-2026-4901 | 6.9 medium | 0.00% | hydrosystem.poznan, control_system | AlanWeb SCADA saves sensitive information into a log file. Critically, user credentials are logged allowing the attacker to obtain further authorized access into the system. Combined with vulnerability CVE-2026-34184, these sensitive information could be accessed by an unauthorized user. This issue was fixed in AlanWeb SCADA version 9.8.5 | Mon 26 Oct |
| CVE-2025-41086 | 6.9 medium | 0.00% | gams | Vulnerability in the access control system of the GAMS licensing system that allows unlimited valid licenses to be generated, bypassing any usage restrictions. The validator uses an insecure checksum algorithm; knowing this algorithm and the format of the license lines, an attacker can recalculate the checksum and generate a valid license to grant themselves full privileges without credentials or access to the source code, allowing them unrestricted access to GAMS's mathematical models and commercial solvers. | 18 Oct |
| CVE-2026-7380 | 6.1 medium | 0.00% | no CPE yet | Improper neutralization of Script-Related HTML tags in a web page (basic XSS) vulnerability in Armiya Information Technologies Ltd. Co. Access Control System (GKS) allows XSS Targeting HTML Attributes. This issue affects Access Control System (GKS): before Version 2. | Sun 25 Oct |
| CVE-2026-8306 | 6.1 medium | 0.00% | no CPE yet | Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in Armiya Information Technologies Ltd. Co. Access Control System (GKS) allows Stored XSS. This issue affects Access Control System (GKS): before Version 2. | Sun 25 Oct |
| CVE-2026-8309 | 5.4 medium | 0.00% | no CPE yet | Improper neutralization of input during web page generation ('cross-site scripting') vulnerability in Armiya Information Technologies Ltd. Co. Access Control System (GKS) allows Reflected XSS. This issue affects Access Control System (GKS): before Version 2. | Sun 25 Oct |
| CVE-2026-17525 | 5.1 medium | 0.00% | no CPE yet | Incomplete cleanup vulnerability in ABB My Control System. This issue affects My Control System: 26.4 and 26.5. | 16 Oct |
15 of 15
Download these 15 as CSV · subscribe to this list.
EPSS scores: 2026-10-30. NVD cursor: 2026-10-29 00:22. The News page shows only notable CVEs (KEV, your stack, new criticals, EPSS over 50%, or active exploitation per SSVC); this table has all of them.