BaselineWatch
58579 CVEs · 127 in KEV
Desk
CVEs known58,579 New, 24 h1,242 Changed, 24 h1,796 In KEV127 Public exploit1,585 Match watchlist0

Vulnerabilities

All My stack Known exploited Public exploit Critical (9+) Likely exploited (EPSS ≥ 50%) Changed, 24 h New, 24 h Sort: risk modified published CVSS EPSS
CVEs
CVECVSSEPSSVendor, productDescriptionModified
CVE-2025-9745 2.0 low 11.0% dlink, di-500wf_firmware A security vulnerability has been detected in D-Link DI-500WF 14.04.10A1T. The impacted element is an unknown function of the file /version_upgrade.asp of the component jhttpd. The manipulation of the argument path leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. 18 Oct
CVE-2025-13306 2.1 low 8.0% dlink, dwr-m920_firmware, dwr-m921_firmware, dir-822k_firmware A security vulnerability has been detected in D-Link DWR-M920, DWR-M921, DIR-822K and DIR-825M 1.1.5. Impacted is the function system of the file /boafrm/formDebugDiagnosticRun. The manipulation of the argument host leads to command injection. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. 18 Oct
CVE-2026-8273 5.1 medium 7.0% dlink, dns-320_firmware A weakness has been identified in D-Link DNS-320 2.06B01. This impacts the function cgi_set_host/cgi_set_ntp/cgi_fan_control/cgi_merge_user of the file /cgi-bin/system_mgr.cgi. This manipulation causes os command injection. It is possible to initiate the attack remotely. Mon 26 Oct
CVE-2025-11665 5.1 medium 7.0% dlink, dap-2695_firmware A vulnerability was detected in D-Link DAP-2695 2.00RC131. This affects the function fwupdater_main of the file rgbin of the component Firmware Update Handler. Performing manipulation results in os command injection. The attack may be initiated remotely. This vulnerability only affects products that are no longer supported by the maintainer. 8 Oct
CVE-2025-12296 2.0 low 7.0% dlink, dap-2695_firmware A security vulnerability has been detected in D-Link DAP-2695 2.00RC13. The impacted element is the function sub_4174B0 of the component Firmware Update Handler. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. This vulnerability only affects products that are no longer supported by the maintainer. 8 Oct
CVE-2026-13545 7.4 high 6.0% dlink, dcs-935l_firmware A vulnerability has been found in D-Link DCS-935L 1.10.01. This affects the function sub_400E40 of the file setconf.cgi of the component POST Parameter Handler. Such manipulation of the argument UID leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Sun 25 Oct
CVE-2025-13562 5.5 medium 6.0% dlink, dir-852_firmware A vulnerability was identified in D-Link DIR-852 1.00. This issue affects some unknown processing of the file /gena.cgi. Such manipulation of the argument service leads to command injection. The attack can be executed remotely. The exploit is publicly available and might be used. This vulnerability only affects products that are no longer supported by the maintainer. 8 Oct
CVE-2025-10814 2.1 low 6.0% dlink, dir-823x_firmware A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. 11 Oct
CVE-2026-8272 2.0 low 6.0% dlink, dns-320_firmware A security flaw has been discovered in D-Link DNS-320 2.06B01. This affects the function delete/rename/copy/move/chmod/chown of the file /cgi-bin/webfile_mgr.cgi. The manipulation results in os command injection. The attack may be performed from remote. The exploit has been released to the public and may be used for attacks. Mon 26 Oct
CVE-2026-5844 7.3 high 5.0% dlink, dir-882_firmware A vulnerability was found in D-Link DIR-882 1.01B02. Impacted is the function sprintf of the file prog.cgi of the component HNAP1 SetNetworkSettings Handler. The manipulation of the argument IPAddress results in os command injection. The attack may be performed from remote. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-8271 2.0 low 5.0% dlink, dns-320_firmware A vulnerability was identified in D-Link DNS-320 2.06B01. The impacted element is the function cgi_speed/cgi_dhcpd_lease/cgi_ddns/cgi_set_ip/cgi_upnp_del/cgi_dhcpd/cgi_upnp_add/cgi_upnp_edit of the file /cgi-bin/network_mgr.cgi. The manipulation leads to os command injection. The attack is possible to be carried out remotely. The exploit is publicly available and might be used. Mon 26 Oct
CVE-2025-11335 2.0 low 5.0% dlink, di-7100g_c1_firmware A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited. 9 Oct
CVE-2025-13305 7.4 high 4.0% dlink, dir-825m_firmware, dwr-m920_firmware, dwr-m921_firmware A weakness has been identified in D-Link DWR-M920, DWR-M921, DWR-M960, DIR-822K and DIR-825M 1.01.07. This issue affects some unknown processing of the file /boafrm/formTracerouteDiagnosticRun. Executing manipulation of the argument host can lead to buffer overflow. The attack may be launched remotely. The exploit has been made available to the public and could be exploited. 18 Oct
CVE-2025-9727 2.1 low 4.0% dlink, dir-816l_firmware A weakness has been identified in D-Link DIR-816L 206b01. Affected by this issue is the function soapcgi_main of the file /soap.cgi. This manipulation of the argument service causes os command injection. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be exploited. This vulnerability only affects products that are no longer supported by the maintainer. 18 Oct
CVE-2025-11092 2.1 low 4.0% dlink, dir-823x_firmware A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub_412E7C of the file /goform/set_switch_settings. This manipulation of the argument port causes command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited. 9 Oct
CVE-2025-11095 2.1 low 4.0% dlink, dir-823x_firmware A vulnerability was detected in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/delete_offline_device. Performing manipulation of the argument delvalue results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used. 9 Oct
CVE-2025-11096 2.1 low 4.0% dlink, dir-823x_firmware A flaw has been found in D-Link DIR-823X 250416. This issue affects some unknown processing of the file /goform/diag_traceroute. Executing manipulation of the argument target_addr can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used. 9 Oct
CVE-2025-11097 2.1 low 4.0% dlink, dir-823x_firmware A vulnerability has been found in D-Link DIR-823X 250416. Impacted is an unknown function of the file /goform/set_device_name. The manipulation of the argument mac leads to command injection. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. 9 Oct
CVE-2025-11098 2.1 low 4.0% dlink, dir-823x_firmware A vulnerability was found in D-Link DIR-823X 250416. The affected element is an unknown function of the file /goform/set_wifi_blacklists. The manipulation of the argument macList results in command injection. The attack may be performed from remote. The exploit has been made public and could be used. 9 Oct
CVE-2025-11099 2.1 low 4.0% dlink, dir-823x_firmware A vulnerability was determined in D-Link DIR-823X 250416. The impacted element is the function uci_del of the file /goform/delete_prohibiting. This manipulation of the argument delvalue causes command injection. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. 9 Oct
CVE-2025-11100 2.1 low 4.0% dlink, dir-823x_firmware A vulnerability was identified in D-Link DIR-823X 250416. This affects the function uci_set of the file /goform/set_wifi_blacklists. Such manipulation leads to command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. 9 Oct
CVE-2025-11407 2.1 low 4.0% dlink, di-7001mini-8g_firmware A weakness has been identified in D-Link DI-7001 MINI 24.04.18B1. Impacted is an unknown function of the file /upgrade_filter.asp. This manipulation of the argument path causes os command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited. 8 Oct
CVE-2025-12313 2.1 low 4.0% dlink, di-7001mini-8g_firmware A vulnerability has been found in D-Link DI-7001 MINI 19.09.19A1/24.04.18B1. The affected element is an unknown function of the file /msp_info.htm. Such manipulation of the argument cmd leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. 8 Oct
CVE-2026-6012 7.4 high 3.0% dlink, dir-513_firmware A security vulnerability has been detected in D-Link DIR-513 1.10. This affects the function formSetPassword of the file /goform/formSetPassword of the component POST Request Handler. The manipulation of the argument curTime leads to buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed publicly and may be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-7067 5.5 medium 3.0% dlink, dir-822_firmware A vulnerability was determined in D-Link DIR-822 A_101. The impacted element is the function system of the file /udhcpcd/dhcpd.c of the component udhcpd DHCP Service. This manipulation of the argument Hostname causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-8344 2.1 low 3.0% dlink, dir-816_firmware A weakness has been identified in D-Link DIR-816 1.10CNB05_R1B011D88210. Affected by this vulnerability is the function sub_445E7C of the file /goform/formDMZ.cgi. This manipulation causes command injection. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be used for attacks. Mon 26 Oct
CVE-2026-8345 2.1 low 3.0% dlink, dir-816_firmware A security vulnerability has been detected in D-Link DIR-816 1.10CNB05_R1B011D88210. Affected by this issue is the function sub_445E7C of the file /goform/singlePortForward. Such manipulation of the argument ip_address leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used. Mon 26 Oct
CVE-2026-8346 2.1 low 3.0% dlink, dir-816_firmware A vulnerability was detected in D-Link DIR-816 1.10CNB05_R1B011D88210. This affects the function portForward. Performing a manipulation of the argument ip_address results in command injection. The attack can be initiated remotely. The exploit is now public and may be used. Mon 26 Oct
CVE-2026-11339 2.1 low 3.0% dlink, dwr-m920_firmware A vulnerability was detected in D-Link DWR-M920 up to 1.1.50. The affected element is the function sub_41CF20 of the file /boafrm/formUSSDSetup. The manipulation of the argument ussdValue results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used. Mon 26 Oct
CVE-2025-14208 2.1 low 3.0% dlink, dir-823x_firmware A security flaw has been discovered in D-Link DIR-823X up to 20250416. This affects the function sub_415028 of the file /goform/set_wan_settings. The manipulation of the argument ppp_username results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be exploited. 14 Oct
CVE-2026-7248 8.9 high 2.0% dlink, di-8100_firmware A vulnerability was found in D-Link DI-8100 16.07.26A1. This affects the function tgfile_htm of the file tgfile.htm of the component CGI Endpoint. The manipulation of the argument fn results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used. Mon 26 Oct
CVE-2025-13188 8.9 high 2.0% dlink, dir-816l_firmware A vulnerability was detected in D-Link DIR-816L 2_06_b09_beta. Affected by this vulnerability is the function authenticationcgi_main of the file /authentication.cgi. Performing manipulation of the argument Password results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. 18 Oct
CVE-2026-7068 7.4 high 2.0% dlink, dir-825_firmware A vulnerability was identified in D-Link DIR-825 3.00b32. This affects the function NMBD_process of the file sserver.c of the component nmbd. Such manipulation leads to buffer overflow. The attack can only be initiated within the local network. The exploit is publicly available and might be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2025-52079 8.8 high 1.0% dlink, dir-820l_firmware The administrator password setting of the D-Link DIR-820L 1.06B02 is has Improper Access Control and is vulnerable to Unverified Password Change via crafted POST request to /get_set.ccp. Tue 27 Oct
CVE-2025-40053 7.5 high 1.0% no CPE yet In the Linux kernel, the following vulnerability has been resolved: net: dlink: handle copy_thresh allocation failure The driver did not handle failure of `netdev_alloc_skb_ip_align()`. If the allocation failed, dereferencing `skb->protocol` could lead to a NULL pointer dereference. This patch tries to allocate `skb`. If the allocation fails, it falls back to the normal path. Tested-on: D-Link DGE-550T Rev-A3 19 Oct
CVE-2026-5979 7.4 high 1.0% dlink, dir-605l_firmware A vulnerability was detected in D-Link DIR-605L 2.13B01. Affected by this vulnerability is the function formVirtualServ of the file /goform/formVirtualServ of the component POST Request Handler. The manipulation of the argument curTime results in buffer overflow. The attack can be launched remotely. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-5980 7.4 high 1.0% dlink, dir-605l_firmware A flaw has been found in D-Link DIR-605L 2.13B01. Affected by this issue is the function formSetMACFilter of the file /goform/formSetMACFilter of the component POST Request Handler. This manipulation of the argument curTime causes buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-5981 7.4 high 1.0% dlink, dir-605l_firmware A vulnerability has been found in D-Link DIR-605L 2.13B01. This affects the function formAdvFirewall of the file /goform/formAdvFirewall of the component POST Request Handler. Such manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-5982 7.4 high 1.0% dlink, dir-605l_firmware A vulnerability was found in D-Link DIR-605L 2.13B01. This vulnerability affects the function formAdvNetwork of the file /goform/formAdvNetwork of the component POST Request Handler. Performing a manipulation of the argument curTime results in buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-5983 7.4 high 1.0% dlink, dir-605l_firmware A vulnerability was determined in D-Link DIR-605L 2.13B01. This issue affects the function formSetDDNS of the file /goform/formSetDDNS of the component POST Request Handler. Executing a manipulation of the argument curTime can lead to buffer overflow. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-5984 7.4 high 1.0% dlink, dir-605l_firmware A vulnerability was identified in D-Link DIR-605L 2.13B01. Impacted is the function formSetLog of the file /goform/formSetLog of the component POST Request Handler. The manipulation of the argument curTime leads to buffer overflow. The attack is possible to be carried out remotely. The exploit is publicly available and might be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-6013 7.4 high 1.0% dlink, dir-513_firmware A vulnerability was detected in D-Link DIR-513 1.10. This vulnerability affects the function formSetRoute of the file /goform/formSetRoute of the component POST Request Handler. The manipulation of the argument curTime results in buffer overflow. The attack may be performed from remote. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-6014 7.4 high 1.0% dlink, dir-513_firmware A flaw has been found in D-Link DIR-513 1.10. This issue affects the function formAdvanceSetup of the file /goform/formAdvanceSetup of the component POST Request Handler. This manipulation of the argument webpage causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used. This vulnerability only affects products that are no longer supported by the maintainer. Mon 26 Oct
CVE-2026-7288 7.4 high 1.0% dlink, dir-825m_firmware A vulnerability has been found in D-Link DIR-825M 1.1.12. This vulnerability affects the function sub_4151FC of the file /boafrm/formVpnConfigSetup. The manipulation of the argument submit-url leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used. Mon 26 Oct
CVE-2026-7289 7.4 high 1.0% dlink, dir-825m_firmware A vulnerability was found in D-Link DIR-825M 1.1.12. This issue affects the function sub_414BA8 of the file /boafrm/formWanConfigSetup. The manipulation of the argument submit-url results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used. Mon 26 Oct
CVE-2025-13189 7.4 high 1.0% dlink, dir-816l_firmware A vulnerability has been found in D-Link DIR-816L 2_06_b09_beta. This affects the function genacgi_main of the file gena.cgi. The manipulation of the argument SERVER_ID/HTTP_SID leads to stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. 18 Oct
CVE-2025-13190 7.4 high 1.0% dlink, dir-816l_firmware A vulnerability was found in D-Link DIR-816L 2_06_b09_beta. This vulnerability affects the function scandir_main of the file /portal/__ajax_exporer.sgi. The manipulation of the argument en results in stack-based buffer overflow. The attack may be performed from remote. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer. 18 Oct
CVE-2025-13191 7.4 high 1.0% dlink, dir-816l_firmware A vulnerability was determined in D-Link DIR-816L 2_06_b09_beta. This issue affects the function soapcgi_main of the file /soap.cgi. This manipulation causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer. 18 Oct
CVE-2025-13304 7.4 high 1.0% dlink, dir-825m_firmware, dwr-m920_firmware, dwr-m921_firmware A security flaw has been discovered in D-Link DWR-M920, DWR-M921, DWR-M960, DWR-M961 and DIR-825M 1.01.07/1.1.47. This vulnerability affects unknown code of the file /boafrm/formPingDiagnosticRun. Performing manipulation of the argument host results in buffer overflow. The attack may be initiated remotely. The exploit has been released to the public and may be exploited. 18 Oct
CVE-2025-13547 7.4 high 1.0% dlink, dir-822k_firmware, dwr-m920_firmware A flaw has been found in D-Link DIR-822K and DWR-M920 1.00_20250513164613/1.1.50. This affects an unknown part of the file /boafrm/formDdns. This manipulation of the argument submit-url causes memory corruption. The attack may be initiated remotely. The exploit has been published and may be used. 18 Oct

50 of 83 · Next

Download these 83 as CSV · subscribe to this list.

EPSS scores: 2026-10-28. NVD cursor: 2026-10-29 00:22. The News page shows only notable CVEs (KEV, your stack, new criticals, EPSS over 50%, or active exploitation per SSVC); this table has all of them.