BaselineWatch
60795 CVEs · 136 in KEV
Desk
CVEs known60,795 New, 24 h1,840 Changed, 24 h2,044 In KEV136 Public exploit1,620 Match watchlist0

Vulnerabilities

All My stack Known exploited Public exploit Critical (9+) Likely exploited (EPSS ≥ 50%) Changed, 24 h New, 24 h Sort: risk modified published CVSS EPSS
CVEs
CVECVSSEPSSVendor, productDescriptionModified
CVE-2025-7328 9.9 critical 1.0% rockwellautomation, 1783-natr_firmware Multiple Broken Authentication security issues exist in the affected product. The security issues are due to missing authentication checks on critical functions. These could result in potential denial-of-service, admin account takeover, or NAT rule modifications. Devices would no longer be able to communicate through NATR as a result of denial-of-service or NAT rule modifications. NAT rule modification could also result in device communication to incorrect endpoints. Admin account takeover could allow modification of configuration and require physical access to restore. 8 Oct
CVE-2025-9064 8.7 high 1.0% rockwellautomation, factorytalk_view A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted. 8 Oct
CVE-2019-25276 8.5 high 0.00% rockwellautomation, studio Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions. Tue 27 Oct
CVE-2025-7329 8.5 high 0.00% rockwellautomation, 1783-natr_firmware A Stored Cross-Site Scripting security issue exists in the affected product that could potentially allow a malicious user to view and modify sensitive data or make the webpage unavailable. The vulnerability stems from missing special character filtering and encoding. Successful exploitation requires an attacker to be able to update configuration fields behind admin login. 8 Oct
CVE-2025-9067 8.5 high 0.00% rockwellautomation, factorytalk_linx A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources. 8 Oct
CVE-2025-9068 8.5 high 0.00% rockwellautomation, factorytalk_linx A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources. 8 Oct
CVE-2026-9127 7.3 high 0.00% rockwellautomation, studio_5000_logix_designer A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality. Sat 24 Oct
CVE-2026-9128 7.3 high 0.00% rockwellautomation, studio_5000_logix_designer A code execution security issue exists within Studio 5000 Logix Designer® due to an unquoted search path in the External Tools configuration. The executable paths specified in the external tools configuration file are not properly quoted, and because these paths contain spaces, the operating system may resolve them to unintended executables placed earlier in the search order. If exploited, an attacker could plant a malicious executable in a location within the search path, resulting in arbitrary code execution with the same permissions of the user running the application. Sat 24 Oct
CVE-2026-8085 7.0 high 0.00% rockwellautomation, arena A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the model.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. Sat 24 Oct
CVE-2026-8312 7.0 high 0.00% rockwellautomation, arena A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the expmt.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. Sat 24 Oct
CVE-2026-8313 7.0 high 0.00% rockwellautomation, arena A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the linker.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. Sat 24 Oct
CVE-2026-8314 7.0 high 0.00% rockwellautomation, arena A security issue exists within Arena® Simulation due to a memory corruption vulnerability in the siman.exe (Siman) component. The vulnerability stems from improper validation of user-supplied data, which can result in an out-of-bounds write. An attacker could leverage this vulnerability to execute arbitrary code in the context of the current process by convincing a user to open a malicious file. Sat 24 Oct
CVE-2025-7330 7.0 high 0.00% rockwellautomation, 1783-natr_firmware A cross-site request forgery security issue exists in the product and version listed. The vulnerability stems from missing CSRF checks on the impacted form. This allows for unintended configuration modification if an attacker can convince a logged in admin to visit a crafted link. 8 Oct
CVE-2025-9063 7.0 high 0.00% rockwellautomation, factorytalk_view An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more. 8 Oct
CVE-2026-9108 5.4 medium 0.00% rockwellautomation, studio_5000_logix_designer A path traversal security issue exists within Studio 5000 Logix Designer® due to improper limitation of file paths within ACD project files. The software does not sanitize or validate file names embedded in the ACD file structure during the project opening procedure, allowing path traversal sequences to escape the intended extraction directory. If exploited, an attacker could craft a malicious ACD project file that results in arbitrary files being written to attacker-controlled locations on the file system, potentially leading to code execution. Sat 24 Oct

15 of 15

Download these 15 as CSV · subscribe to this list.

EPSS scores: 2026-10-30. NVD cursor: 2026-10-29 00:22. The News page shows only notable CVEs (KEV, your stack, new criticals, EPSS over 50%, or active exploitation per SSVC); this table has all of them.