| CVE | CVSS | EPSS | Vendor, product | Description | Modified |
|---|---|---|---|---|---|
| CVE-2023-2186 | 9.8 critical | 1.0% | trianglemicroworks, scada_data_gateway | On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution. | Fri 23 Oct |
| CVE-2023-2187 | 5.3 medium | 1.0% | trianglemicroworks, scada_data_gateway | On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events. | Fri 23 Oct |
2 of 2
Download these 2 as CSV · subscribe to this list.
EPSS scores: 2026-10-28. NVD cursor: 2026-10-29 00:22. The News page shows only notable CVEs (KEV, your stack, new criticals, EPSS over 50%, or active exploitation per SSVC); this table has all of them.